Adapt and Change

FEATURES

Battery Reverse Connection Protection with Fuse Switch, Safer Installation
PF1.0, High Efficiency, Lower Consumption,Energy Conservation/ Environmental Protection/Electricity Saving/Cost Saving
Parallel Function Up to Maximum 9 Units: Enlarge More Loads
High Precision of Output Voltage,±5%, Take Care of Your Appliances
Communication Option: External WIFI, Supervise at Any Time
BMS function for lithium battery

TECHNICAL DATA

Model NXT-11000H NXT-11000HP
Voltage Range 90-280VAC±3V(Inverter Mode)  170-280VAC±3V(UPS Mode)
Rated Output Power 11000W
Output Voltage(AC) 220/230/240VAC±5%
Output Frequency 50/60Hz±0.1%
Waveform Pure sine wave
Peak Power 22000VA
Overload Capacity(Battery Mode) 21s@105%~150% Load      11s@150%~200% Load    400ms@>200% Load
Grid connected Operation Output Voltage 220/230/240VAC
Grid Voltage Range 195-253VA
Output Current 47.8A
Peak Efficiency(Battery Model) 98%
Norminal Voltage 48VDC
Float Charging Voltage 54VDC
Max PV Input Power 2*7500W
MPPT Controller Voltage 90-500VDC
MAX PV Input Voltage 500VDC
MAX PV Charge Current 150A
MAX AC Charge Current 150A
MAX Charge Current 150A
RS232 5PIN/Pitch2.0mm
Expansion Slot Communication Interface 2×5PIN/Pitch2.54mm,Lithium battery BMS communication card、WIFI, etc
Parallel Interface Not Support Parallel Max 9 parallel machipes
Operating Temperature 0~40°C
Humidity 20%~95%(Non-condensing)
Storage Temperature -15~60℃
Noise(dB) ≤50db
L*W*H(mm) 571*500*148mm